Product Model: HZ
Use, the first container placed fixture, turn on the power to ON file, you can set the desired speed and timing.
Example: Set the oscillator to 150 per minute oscillation 5.5 child stop work.
1, the closure of the power switch, then displayed as the original rotational speed value. The running speed of the (last).
2 Press SET Form F-01 into the timing set. Press the SET button to enter the setup
Press ▲ ▼ to display a set to run regularly, such as the timing set to 0 (normally open) run.
3, and then press SET to confirm (should be dripping sound).
Exit, press "?" (-01)
5 Press ▲ show F-02 into the timing
Press SET to show the original length value (last timing length)
Press ▲ ▼ to display digital size change final choice of 5.5 (minimum resolution of 0.1 hours, 6 minutes).
Press SET to confirm (should be dripping sound). 5.5 hours from time to time been recognized.
6, and then press the "?" secondary exit the setting to display the value of raw speed.
Press ▲ ▼ to set the speed of 150
Press RUN to start the machine can slowly start until 150 rev / min. And stable operation of the 5.5 child stop and alarm 10 seconds prompt. The timing has finished running.
7 Press the STOP at any time to stop running.
8, the speed setting Press ▲ ▼ to set in a stopped state.
9, POW power indicator, ALM fault light, RUN to run lights STOP as stop lights. The corresponding indicator controller for the corresponding state.