伺服閥R901066145 4WS2EM10-5X/75B11ET315K8DV
伺服閥R901066145 4WS2EM10-5X/75B11ET315K8DV
R901066145 4WS2EM10-5X/75B11ET315K8DV
R901506730 4WS2EM6-2X/5B11XLET315K17EV-102
R900974304 4WS2EM6-22/5B11ET210K17EV
R900961252 4WS2EM10-4X/10B3T315K8DV-24停產,升級5X
R900378570 4WS2EM10-4X/20B2ET315Z8DM由下述型號組合替代: 4WS2EM10-5X/20B11ET315K8DV+Z8
R900772317 4WS2EM10-5X/60B11T315K31CV-114
R900956598 4WS2EM10-51/75B11T315K31DV
R900956128 4WS2EM10-5X/10B11ET315K31EV
R900781091 4WS2EM10-52/30B11ET315K31BV
R900949285 4WS2EM10-51/30B11ET315K31EV
R900922801 4WS2EM10-5X/90B11ET315K31EV
R900243941 4WS2EM10-51/75B11ET315K31DV
R901020256 4WS2EM10-5X/60B11ET315K8DV
R901043430 4WS2EM10-5X/30B11ET315K8AV
R901237664 4WS2EM10-5X/90B11XNT210K31EV-102
R900571581 4WS2EM10-4X/60B2ET315K8EM-26
R900949286 4WS2EM10-5X/60B11ET315K31EV
R901020256 4WS2EM10-5X/60B11ET315K8DV
R900931560 4WS2EM16-2X/150B12ET315K8DM
R901020256 4WS2EM10-5X/60B11ET315K8DV
R900750593 4WS2EM10-5X/10B11ET315K8BV
伺服閥的故障常常在電液伺服系統調試或工作不正常情況下發現的。所以這里有時是系統問題包括放大器、反饋機構、執行機構等故障,有時確是伺服閥問題。所以首先要搞清楚是系統問題、還是伺服閥問題。解決這疑問的常用辦法是:
一、有條件的將閥卸下,上實驗臺復測一下即可。
二、大多數情況無此條件,這時一個簡單的辦法是將系統開環,備用獨立直流電源、經萬用表再給伺服閥供正負不同量值電流,從閥的輸出情況來判斷閥是否有毛病,是什么毛病。伐問題不大,再找系統問題,例如:執行機構的內漏過大,會引起系統動作變慢,滯環嚴重、甚至不能工作;反饋信號斷路或失常等等,放大器問題有輸出信號畸變或不工作,系統問題這里不祥談,