ZT-III desktop vacuum minipump product information guide
Introduction
ZT-III desktop vacuum minipump is designed for chemical testing, clinical testing, bio-engineering, metallurgy, environmental protection. This vacuum decompressing device can draw and discharge liquid as well as decompression. It is widely applied to extract supernate or sediment after centrifugation in extraction & preparation of monoclonal antibodies ,clearing or exchanging liquid after integration, washing porous plastic plate for enzyme-linked immunosorbent, leaching experiment-like points of hybridization, rapid extraction in the sub-photometer ( device with pool) or a variety of biochemical-analytic instruments, replacing the current impact of the glass vacuum pumps. A multifunctional instrument, with reasonable mechanism, low noise and easy to carry, greatly facilitates the work of the laboratory.
Main technical indicator
Negative Pressure Range: 0.01Mpa-0.075Mpa Degree of Vacuum: ≥0.075Mpa
Maximum Flux: 6L/min Weight: 7Kg Power: AC220V
Size: 290×240×110MM Rated Power: 20W Content of Bottle: 1000ML
Instruction
- Plug the bottle(no leakage), access to power, then turn on power to start working.
- Exhaust: remove the stainless steel needle and insert in exhaust port, regulating negative pressure according to the experiment.
- Pumping liquid: access to power and turn the negative pressure knob to the lower, then choose two stainless needles of different diameters to draw liquid according to requirement.
A Extraction of the supernate after centrifugation: as a small amount of supernate has been pumped into the bottle, it can not be collected. Please prepared a vial (such as penicillin bottles). Pull out the stainless steel needles from rubber plug, and insert in the penicillin bottles (or on the other cork). After the start, gradually turning up the negative pressure, supernate can be pumped into bottle. Do not get the bottle full of the sample to avoid being drawn into the pump.
B Extraction of the sediment after centrifugation: First remove the centrifuge tube. After the start, slowly turn up large negative pressure, and carefully draw out supernate into the bottle collecting waste water with stainless steel needles. Thus the sediment needed is left in the heart of tube. Note: You’d better slowly approach the liquid with the fine needle, so as to avoid drawing out the sediment.
- In order to avoid contamination, we suggest you sterilize the needle after using or buy more needles from us in advance.
- Please turn off the power when finished.
Notice
- Don’t insert the big needle in the plug too deep to avoid drawing liquid into the pump.
- Please pump clean water into rubber tube several times to wash up the leftover of samples after using. Finally, wash up the used bottle for next use.
Shanghai Zhisun Equipment Co., Ltd
Address: Block 58 NO. 3333 Gudai Road Shanghai Postcode: 201100
ephone: 021-51510737 51510738 021-51510736
Website: www.zhisun。。com : zhx@zhisun.com
免責聲明
- 凡本網注明“來源:化工儀器網”的所有作品,均為浙江興旺寶明通網絡有限公司-化工儀器網合法擁有版權或有權使用的作品,未經本網授權不得轉載、摘編或利用其它方式使用上述作品。已經本網授權使用作品的,應在授權范圍內使用,并注明“來源:化工儀器網”。違反上述聲明者,本網將追究其相關法律責任。
- 本網轉載并注明自其他來源(非化工儀器網)的作品,目的在于傳遞更多信息,并不代表本網贊同其觀點和對其真實性負責,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網站或個人從本網轉載時,必須保留本網注明的作品第一來源,并自負版權等法律責任。
- 如涉及作品內容、版權等問題,請在作品發表之日起一周內與本網聯系,否則視為放棄相關權利。