  • 94123A-3a太陽光模擬器
貨物所在地:
浙江杭州市
更新時間:
2021-11-27 21:00:07
有效期:
2021年11月27日 -- 2022年5月27日
已獲點擊:
540
在線詢價 收藏產品

(聯系我們,請說明是在 化工儀器網 上看到的信息,謝謝!)

產品簡介

Oriel Sol3A Solar Simulators maintain Class AAA compliance during the rated “performance lifetime" of the lamp.

詳細介紹

Oriel Sol3A Class AAA Solar Simulators

?Leveraging over 40 years of experience in light source and power supply design, Newport’s Oriel® brand is proud to introduce the latest innovation in solar simulators – the Oriel Sol3A™ Class AAA Solar Simulator family. The product family includes:

Model 94123A = 12 x 12 inch Beam Size
Model 94083A = 8 x 8 inch Beam Size
Model 94063A = 6 x 6 inch Beam Size
Model 94043A = 4 x 4 inch Beam Size
Model 94023A = 2 x 2 inch Beam Size

All Oriel Sol3A solar simulators are certified to IEC 60904-9 Edition 2 (2007), JIS C 8912, and ASTM E927-5 standards for Spectral Match, Non-Uniformity of Irradiance, and Temporal Instability of Irradiance. By convention, Class AAA is reported with the first letter representing Spectral performance, the second letter Uniformity of Irradiance, and the third letter Temporal Stability. The Oriel SOL 3A solar simulators all use a single lamp design to meet not one or two, but all three performance criteria without compromising the 1 Sun output power, providing true Class AAA performance. The Oriel Sol3A uses a black non-reflective finish to minimize stray light and incorporates captive screws for all panels requiring user access to facilitate lamp replacement, alignment, and filter changes. Safety interlocks prevent inadvertent exposure to UV light. The Oriel Sol3A rugged design is backed by the Newport Corporation's world wide organization.

Table 1 Class AAA Standards and Specifications

Organization IEC JIS ASTM
Performance Parameter 60904-9-2007 C 8912 E92-05
Spectral Match
(fraction of ideal percentage)
0.75 - 1.25 0.75 - 1.25 0.75 - 1.25
Non-Uniformity of Irradiance 2.0% <±2% 2%
Temporal Instability 0.5% STI <±1% 2%
  <2.0% LTI    

Spectral Match

The standards define the spectral match of a solar simulator as a percentage of the integrated intensity in 6 spectral ranges (listed in Table 2). Any deviation from the specified percentages must then lie within a range that determines the class of the simulator. For Class AAA, this range is 0.75 to 1.25 times the ideal percentage.

Spectral Match

Table 2 Ideal Spectral Match Defined by IEC Standards

Spectral Range (nm) Total Irradiance Range (%) Ideal %
400 - 500 13.9 - 23.1 18.5
500 - 600 15.1 - 25.1 20.1
600 - 700 13.7 - 22.9 18.3
700 - 800 11.1 - 18.5 14.8
800 - 900 9.2 - 15.3 12.2
900 - 1100 12.1 - 20.1 16.1
Spectral Uniform Fig2Fig. 1 Oriel Sol3A Spectral Match with AM 1.5G spectral correction filter meets IEC, JIS, ASTM Class A requirements to for spectral match.

Spatial Uniformity of Irradiance

The irradiance uniformity over the work area is the most difficult Class AAA requirement to achieve and maintain. Hot spots can lead to significant errors in measured cell efficiency and can cause inaccurate binning of cells. The Class AAA spatial non-uniformity performance standard is designed to minimize the impact of hot spots and has a very stringent requirement of ≤2%. The plot below shows the uniformity of the irradiance across a typical simulator working area. Each unit will come with a plot of irradiance non-uniformity. The working distance ranges for each simulator are listed in Table 3.

Sol3A Working Distances

Table 3 Working Distances

Model Size Working Distance Range (Inches)
94023A 2 x 2 (50.8 x 50.8) 12.0 ±0.5
94043A 4 x 4 (101.6 x 101.6) 4.0 ±0.5
94063A 6 x 6 (152.4 x 152.4) 5.0 ±0.5
94083A 8 x 8 (203.2 x 203.2) 15.0 ±0.5
94123A 12x12 (304.8 x 304.8)  
Irrad Uniform Plot Fig3Fig. 2 Measured Uniformity of a 2x2” Oriel Class AAA Solar Simulator.

Temporal Instability

Temporal Instability is the third performance parameter of Class AAA standards. It requires that the output light be stable over time in order to ensure that the lamp fluctuations do not distort the measurement of solar cell efficiency. Oriel’s Sol3A easily meets the requirements for temporal instability as defined by the IEC, ASTM, and JIS standards. The IEC 60904-9 (2007) has the most stringent requirements for short term instability with a maximum allowable level of 0.5%. Figure 4 shows a typical instability response for an Oriel Sol3A utilizing a 50 millisecond data acquisition time.

Elapsed Time (sec) 60
No. of Data Points 1200
% Instability 0.369
Temporal Fig4Fig. 3 Typical Output Variation of a 1.6 kW Oriel Sol3A Solar Simulator Over Time.

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~
二維碼 意見反饋
在線留言
主站蜘蛛池模板: 熟女老妇久久视频| 日韩欧美三级在线| 国产VA精品午夜福利视频| 亚洲深深色噜噜狠狠爱| 午夜精品白在线观看| 91精品国产综合久久久欧美| 欧美精品黄页在线观看视频| 日韩一级片久久| 亚洲中文字幕无码永久在线| 18女下面流水不遮网站免费| 国产又黄又爽又猛免费app| 日本午夜精品一区二区三区电影| 亚洲第一激情| 高清AV熟女一区| 欧美精品一区二区三区四区| 永久免费精品精品永久-夜色| 国内精品51视频在线观看| 一区二区三区国产亚洲网站| 欧美 亚洲 综合 在线| 99精品日韩欧美在线观看| 无码又爽又刺激视频A片涩涩| 日本高清在线一区二区三区| 亚洲一区日韩精品颜射| 播放男人添女人下边视频| 亚洲精品乱码久久久久久按摩| 7788人成免费看A片| 韩国办公室三级HD激情在线观看| 欧美熟妇丰满肥白大屁股免费视频| 粗大挺进玉芬双腿间| 中文字幕人妻熟女人妻洋洋| 国产精品久久久久久亚瑟影院| 久久久日韩欧美| 精品久久久麻豆国产精品| 爱久久AV一区二区三区色欲| 少妇高潮毛片免费看A片| 久久久久久久久中文字幕| 成年黄网站免费大全毛片| 久久9热这里只有精品| 日本黄片日本黄片| 日韩黄色一级黄色片| 国产二级一片内射视频插放|