Industry standard, CL17 Free Chlorine Analyzer with AquaTrend Network. Included with the CL17 analyzer is a 1 month supply of DPD indicator and Free Chlorine indicator and buffer solutions, an install

Accurate, Reliable Results

The Hach CL17 Chlorine Analyzer uses colorimetric DPD chemistry to monitor water continuously for free or total residual chlorine. The CL17 is a simple, dependable and economic solution, and the preferred choice to high-maintenance instruments that require frequent calibration. The CL17 analysis method is robust and not affected by changes in chlorine concentration, sample pH, temperature, flow, or pressure, thus offering more accuracy and reliability than alternative instruments and technologies.

Simple, Predictable Maintenance

Monthly routine maintenance for the CL17 can typically be performed in 15 minutes and includes changing reagents and cleaning the colorimetric cell. No special tools are required. For typical use, the CL17 will operate unattended for 30 days. Challenging applications may require more frequent cleaning.

Factory Calibrated

The CL17 Chlorine Analyzer is factory calibrated. A built-in electronic calibration curve is preprogrammed into the instrument. This instrument does not require recalibration unless specified by your regulatory agency for compliance reporting purposes.

EPA Compliant

The CL17 is compliant with US EPA regulation 40 CFR 140.74, and both Method 4500-CL G and Method 334.0 can be used for measurement of residual chlorine in drinking water.

Pump Control

Both an alarm for manual chlorine feed control and a 4-20 mA output for automatic control of chlorine feed pumps is available on the CL17 Analyzer.

What's in the box

Hach CL17 Chlorine Analyzer with AquaTrend Circuit Board, a one-month supply of reagents, 100 mL of Sulfuric acid, Maintenance kit, Installation kit, and Manual. (The power cord is ordered separay.)

Specifications

Accuracy:± 5 % or ±0.03 mg/L (ppm) as CL2, whichever is greater

Air Purge:0.1 cfm (0.17 m³/h) instrument quality air at max. 20 psig (ca. 1.4 bar)

Alarm:Two alarms selectable for sample concentration alarm, analyzer system warning, or analyzer system shut-down alarm. Each is equipped with an APDT relay with contacts rated for 5A resistive load at 230 V AC.

Certifications:CE Approved
ETL Listed to UL 1262
ETL Certified to CSA 22.2 No. 142

Cycle Time:2.5 minutes

Dimensions (H x W x D):37.1 in x 16.5 in x 7.5 in (943 mm x 419 mm x 191 mm)

Display:LCD, 3-1/2 inch digit measurement readout and six-character alphanumeric scrolling text line

Drain:1/2-inch ID flexible hose, hose barb

Enclosure Construction:ABS plastic, two clear polycarbonate windows, IP62-rated with the gasketed door latched.

Inlet:1/4-inch OD polyethylene tube, quick-disconnect fitting

Interferences:Other oxidizing agents such as bromide, chlorine dioxide, permanganate and ozone will cause a positive interference. Hexavalent chromium will cause a positive interference: 1 mg/L Cr?? = approximay 0.02 mg/L as Cl?. Hardness must not exceed 1,000 mg/L as CaCO?.

Light Source:Class 1 LED (light emitting diode) with a peak wavelength of 520 nm; 50,000 hours estimated minimum life

Lower Limit of Detection (LOD):0.03 mg/L (ppm)

Mounting:Wall mount

Operating Humidity:90% at 40 °C (90% at 104 °F) maximum

Operating Temperature Range:5 to 40 °C (41 to 104 °F)

Power Requirements (Amps):2.5 A

Power Requirements (Hz):50/60 Hz

Power Requirements (Voltage):100 - 115/230 V AC

Pressure Limit:Inlet Pressure to Sample Conditioning: 1.5 to 75 psi (0.1 bar to 5.2 bar)

Range:0 to 5 mg/L free or total residual chlorine

Ranges:0 to 5 mg/L free or total residual chlorine

Repeatability:0.01 ppm or 3.0 % , whichever is greater

Sample Flow Rate:200 to 500 mL per minute minimum required

Sample Temperature:5 to 40 °C (41 to 104 °F)

Weight:24.91 lbs. (11.3 kg)

- See more at: http://www.hach.com/cl17-free-chlorine-analyzer-with-aquatrend-network/product-details?id=7640295863&callback=qs#sthash.hQR8UA9t.dpuf

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

您的留言已提交成功!我們將在第一時間回復您~
在線留言

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:
熱線電話 在線詢價
主站蜘蛛池模板: 欧美精品一区二区少妇免费A片| 97色伦图片97色伦图影院久久| 污污污视频在线观看无码| 亚洲AV无码A片一区二区三区| 国产JK白丝喷白浆精品视频| 小妖精抬起臀嗯啊H快穿| 校园高H校草深一点H| av免费无码天堂在线| 少妇被躁爽到高潮无码久久| 免费无码又爽又刺激A片小说| 日韩欧美在线中文字幕| 欧美亚洲国产成人精品| 91精品啪国产在线观看| 亚洲精品乱码8久久久久久日本| aaaaaaa一级毛片| 国产AV一区二区三区天堂综合网| 性色AV久久一区二区| 久久久久久久久四区三区| 美女赤裸露私密部位图片| 99久久这里只精品国产免费| 日本一区久爱精品免费| 在线va无卡无码高清| 久久精品99国产精品亚洲| 久久精品国产亚洲av精东| 女人麻豆国产香蕉久久精品| 欧美日韩免费在线看| 啊老师用力小雪好棒| 神电影院午夜dy888我不卡| 少妇的肉体AA片免费| 伦交乱口述| 亚洲av日韩久久久久久久| loveme枫和铃声樱花| 国产精品久久久久久av| 国产精品久久久久久福利| 中文字幕人妻丝乱一区三区| 国产精品,欧美精品| 日日摸夜夜添夜夜添A片二维码| 男女无遮挡猛进猛出免费观看视频| 在线看免费做爰60分钟视频| 涩涩片大全百度影音| 国产亚洲精品久|