美國(guó)SKC Biolite微生物采樣泵
- 公司名稱 上海京燦精密機(jī)械有限公司
- 品牌 SKC/美國(guó)
- 型號(hào)
- 產(chǎn)地 美國(guó)SKC
- 廠商性質(zhì) 生產(chǎn)廠家
- 更新時(shí)間 2017/8/4 17:24:24
- 訪問次數(shù) 1889
聯(lián)系方式:馮軍17717563696 查看聯(lián)系方式
聯(lián)系我們時(shí)請(qǐng)說明是化工儀器網(wǎng)上看到的信息,謝謝!
德爾格壓縮空氣質(zhì)量檢測(cè)儀,德爾格氣體檢測(cè)儀,BW氣體檢測(cè)儀,BW四合一氣體檢測(cè)儀,華瑞四合一氣體檢測(cè)儀。氣體檢測(cè)儀、濁度計(jì)、PH計(jì)、巴氏硬度計(jì)、非標(biāo)自動(dòng)化設(shè)備、壓力校驗(yàn)儀、壓力傳感器、儀器儀表、設(shè)備租賃、檢測(cè)服務(wù)
美國(guó)SKC Biolite微生物采樣泵
技術(shù)參數(shù):
zui大流速M(fèi)aximum flow rate: 30.5 litre/min;
背壓流速:Maximum back pressure: 800mbar;
尺寸:Dimensions: W x H x D 162 x 209 x 338mm;
重量:Weight: 6.05kg;
防護(hù)等級(jí)Enclosure rating - IP20
操作溫度Operating temperature: 0°C to +40°C
操作濕度Operating humidity: 0 to 95% Rh
電壓Mains supply: 220/230V ~ 50Hz
電流Maximum input current: 0.66A
噪音Operating noise level: 67 - 71dBA @ 1metre
找到一個(gè)合適的電源插座,在泵背部插入電源引入IEC電源,規(guī)格為:英國(guó)3針和2歐元引腳電源引線,選擇正確插頭。
打開流量調(diào)節(jié)器,*逆時(shí)針方向以確保它是*開放的,然后打開電源開關(guān)。
打開泵的開/關(guān),使泵運(yùn)行五~十分鐘穩(wěn)定之前任何流量校準(zhǔn),關(guān)機(jī),停止泵。
打開泵的開關(guān)。如果使用流量調(diào)節(jié)器需要調(diào)節(jié)流量。打開流量調(diào)節(jié)器順時(shí)針和逆時(shí)針降低流動(dòng)率增大流量。使泵運(yùn)行五分鐘,流量穩(wěn)定在采取任何刻度讀數(shù)。當(dāng)所需的流量已定,流量調(diào)節(jié)器可以用鎖緊螺母鎖緊。
背壓力表給出一個(gè),這個(gè)指示的SKC BioSampler正確操作r達(dá)到吸15in汞音速。
Insert the mains lead into the IEC mains inlet at the rear of the pump and plug the lead into a suitable mains outlet socket. Both UK 3 pin and Euro 2 pin mains leads are supplied with the unit, select the correct lead for your location.
Turn the flow adjuster fully counter-clockwise to ensure that it is fully open. Switch on the mains supply.
Switch on the pump using the on/off switch at the rear of the pump. Allow the pump to run for five to ten minutes to stabilise before commencing any flow calibration. Switch the pump off using the on/off switch at the rear of the pump.
Connect the sample train to the pump inlet hosetail. Switch on the pump using the on/off switch. Adjust the flow rate if required using the flow adjuster. Turn the flow adjuster clockwise to reduce the flow rate and anti-clockwise to increase the flow rate. Allow the pump to run for five minutes for the flow rate to stabilise before taking any calibration readings. When the desired flow rate has been set, the flow adjuster can be locked using the locking nut.
The back pressure gauge gives a reading of the suction generated by the pump due to the restriction to flow of the sample train. This is important for indicating correct operation of the SKC Biosampler - the Biosampler achieves sonic flow at a suction of 15in Hg (refer to the Biosampler instructions for further details).
美國(guó)SKC具備優(yōu)秀的樣品泵,如AIRCHEK2000美國(guó)SKC,升級(jí)版airchek touch,通用泵和XR5000氣體采樣泵,提供*品質(zhì)的實(shí)驗(yàn)室和工業(yè)檢測(cè)儀器設(shè)備。通過專業(yè)、細(xì)致和全面的服務(wù)實(shí)現(xiàn)為客戶創(chuàng)造更多價(jià)值。
相關(guān)分類
- 煙氣分析儀
- 甲醛分析儀
- 粉塵測(cè)定儀/粉塵儀
- 紅外線氣體分析儀
- 多組分氣體分析儀
- 一氧化碳分析儀
- 二氧化碳分析儀
- 氨氣分析儀/氨分析儀
- 汽車尾氣分析儀
- 有毒有害氣體監(jiān)測(cè)儀
- 臭氧檢測(cè)儀
- 煙氣/大氣重金屬在線分析儀
- 高純氣/特氣分析系統(tǒng)
- VOC檢測(cè)儀/TVOC檢測(cè)儀
- 臭氧分析儀(O3)
- 熱導(dǎo)式氣體分析儀
- CO、SO2、HCL、NOX、空氣檢測(cè)儀
- PM2.5/PM10/PM1/TSP大氣顆粒物監(jiān)測(cè)儀
- 甲烷/非甲烷烴檢測(cè)儀
- 氮氧化物分析儀(NOX)
- 油煙檢測(cè)儀
- 惡臭測(cè)定儀
- 粉塵采樣器
- 粒子計(jì)數(shù)器
- 煙塵采樣器、煙氣采樣器
- 顆粒物采樣器
- 零氣發(fā)生器
- TSP采樣器
- 空氣微生物采樣器
- PM2.5采樣器
- PM10采樣器
- 粗、細(xì)顆粒物雙道采樣器
- 二噁英采樣儀/二噁英采樣器
- 酸雨采樣器
- 激光雷達(dá)
- 太陽(yáng)光度計(jì)
- 塵量分析儀
- 氣體稀釋儀
- 煙度計(jì)
- 氣溶膠
- 氣體在線自動(dòng)監(jiān)測(cè)系統(tǒng)
- 灰霾監(jiān)測(cè)系統(tǒng)
- 空氣質(zhì)量自動(dòng)監(jiān)測(cè)系統(tǒng)
- 煙氣汞連續(xù)監(jiān)測(cè)系統(tǒng)
- 氣體報(bào)警器/探測(cè)器/傳感器
- 環(huán)境污染事故應(yīng)急監(jiān)測(cè)儀器
- 溫室氣體監(jiān)測(cè)儀
- 蘇瑪罐采樣器
- 揚(yáng)塵監(jiān)測(cè)儀
- 降水/降塵自動(dòng)采樣監(jiān)測(cè)儀
- 煙氣汞采樣器
- 氨逃逸在線監(jiān)測(cè)系統(tǒng)
- 粒徑譜儀
- 其它氣體檢測(cè)